onitor)模式命令.当/dev/md1阵列中的一个磁盘/dev/sdi1失效时,mdadm会自动从/dev/md0组中上移走spare磁盘,并加入/dev/md1中.

  [root@fc5 mdadm-2.6.3]#./mdadm --monitor --mail=root@localhost --syslog --program=/root/md.sh

  --delay=300 /dev/md* --daemonise

  8105

  [root@fc5 mdadm-2.6.3]#./mdadm /dev/md1 -f /dev/sdi1

  mdadm: set /dev/sdi1 faulty in /dev/md1

  [root@fc5 mdadm-2.6.3]#./mdadm -D /dev/md1

  /dev/md1:

  Version : 00.90.03

  Creation Time : Mon Aug 23 00:10:00 1999

  Raid Level : raid5

  Array Size : 2096896 (2048.09 MiB 2147.22 MB)

  Used Dev Size : 1048448 (1024.05 MiB 1073.61 MB)

  Raid Devices : 3

  Total Devices : 4

  Preferred Minor : 1

  Persistence : Superblock is persistent

  Update Time : Mon Aug 23 00:13:15 1999

Empire CMS,phome.net

  State : clean, degraded, recovering

  Active Devices : 2

  Working Devices : 3

  Failed Devices : 1

  Spare Devices : 1

  Layout : left-symmetric

  Chunk Size : 64K

  Rebuild Status : 78% complete

  UUID : 34d3de75:6912dc24:e1316607:4e72cd01

  Events : 0.4

  Number Major Minor RaidDevice State

  3 8 112 0 spare rebuilding /dev/sdh

  1 8 145 1 active sync /dev/sdj1

  2 8 161 2 active sync /dev/sdk1

  4 8 129 - faulty spare /dev/sdi1

  6. 多种元数据格式

  目前MD设备有两种主要的元数据格式(0.9版本和1.x版本),主要是元数据占用的空间不同和支持的底层设备个数不同,1.x版本还可以指定元数据写入设备的具体位置(1.0为在设备尾部,1.1为在设备开始,1.2为在设备开始的4KB位置).创建阵列通过--metadata(或者其缩写-e)参数来指定元数据格式版本.

  [root@fc5 mdadm-2.6.3]# ./mdadm -CR /dev/md0 -l5 -n6 -x1 /dev/sd[b-h]

  [root@fc5 mdadm-2.6.3]# ./mdadm -D /dev/md0 | grep Version

  Version : 00.90.03

  [root@fc5 mdadm-2.6.3]# ./mdadm -CR /dev/md0 -l5 -n6 -x1 -e1.0 /dev/sd[b-h]

  [root@fc5 mdadm-2.6.3]# ./mdadm -D /dev/md0 | grep Version

  Version : 01.00.03

  [root@fc5 mdadm-2.6.3]# ./mdadm -CR /dev/md0 -l5 -n6 -x1 -e1.1 /dev/sd[b-h]

  [root@fc5 mdadm-2.6.3]# ./mdadm -D /dev/md0 | grep Version

  Version : 01.01.03

  [root@fc5 mdadm-2.6.3]# ./mdadm -CR /dev/md0 -l5 -n6 -x1 -e1.2 /dev/sd[b-h]

  [root@fc5 mdadm-2.6.3]# ./mdadm -D /dev/md0 | grep Version

  Version : 01.02.03

  当阵列将磁盘移走后,也使用--zero-superblock清空设备上面的元数据信息.

  [root@fc5 mdadm-2.6.3]# ./mdadm -Es /dev/sdh

  ARRAY /dev/md0 level=raid5 num-devices=6

  UUID=acd2b182:4695ee20:37689502:eb0423e1

  spares=1

  [root@fc5 mdadm-2.6.3]# ./mdadm /dev/md0 -f /dev/sdh -r /dev/sdh

  mdadm: set /dev/sdh faulty in /dev/md0

  mdadm: hot removed /dev/sdh

  [root@fc5 mdadm-2.6.3]# ./mdadm --zero-superblock /dev/sdh

Empire CMS,phome.net

  [root@fc5 mdadm-2.6.3]# ./mdadm -Es /dev/sdh

  [root@fc5 mdadm-2.6.3]#

  7. 可分区的RAID设备

  如果想对支持分区的MD设备(Partitionable raid array)进行分区,需

凌众科技专业提供服务器租用、服务器托管、企业邮局、虚拟主机等服务,公司网站:http://www.lingzhong.cn 为了给广大客户了解更多的技术信息,本技术文章收集来源于网络,凌众科技尊重文章作者的版权,如果有涉及你的版权有必要删除你的文章,请和我们联系。以上信息与文章正文是不可分割的一部分,如果您要转载本文章,请保留以上信息,谢谢!

分享到: 更多

Copyright ©1999-2011 厦门凌众科技有限公司 厦门优通互联科技开发有限公司 All rights reserved

地址(ADD):厦门软件园二期望海路63号701E(东南融通旁) 邮编(ZIP):361008

电话:0592-5908028 传真:0592-5908039 咨询信箱:web@lingzhong.cn 咨询OICQ:173723134

《中华人民共和国增值电信业务经营许可证》闽B2-20100024  ICP备案:闽ICP备05037997号